Keep everyone in your establishment safe during fire circumstances with Yun-Yang’s design and manufacturing of fire safety equipment.



Know more about Fire Detection and Alarm Systems:

Securing Your Office with a Fire Alarm and Detection System (FDAS)

Fire Detection and Alarm Systems are intended to determine fires early in their development when time will still be available for the safe evacuation of the people. Early detection also plays an important role in protecting the safety of emergency response workforces.

Read more

Integrating Different Products for BMS

Fire Detection and Alarm Systems provides the ability to immediately recognize short circuits/cut lines and all other kinds of faulty wiring in the system and isolate it from the rest as precaution.



Read more


YFPR-3 Intelligent Fire
Alarm Control Panel

  • English LCD Screen:The Operation Board has the 128 x 64 (or 64 English characters)

    LCD Screen designed with text-guided interface to display on-site statuses correctly.

    It’s easy and simple to read and operate.

  • Auto-test Function:Select disconnection or activation test to test for each zone
  • Connection to synchronic annunicator, LCD annunicator or monitor graphic annunicator,

    display with floor plan for alarm zone

  • Historical Alarm Data:Alarm history can record up to 500 items, available for

    relative staffs’ inspect and survey.

  • Two Stage Alarm Delay Function:After detecting fire, the system will automatically reset detectors

    to process second stage alarm delay inspect. It reduces false alarms caused by

    general wire interrupting, promoting the reliability of the fire alarm control panel.

  • LED display for Zone Circuit Statuses:Each zone board module is with 5 zone

    states display. Each zone is with LED 3 status display (ordinary: off,

    disconnection: flashing, activate: on)

  • Sound Guidance Function:System with operating guidance voice for abnormal state,

    to give management staffs a clear understanding of the abnormal state.

  • Protection against Lightening Surge:Power supply module with protection

    against lightening surge to avoid central computer damage caused by high voltage

    or power surge

  • Abnormal Voltage Inspection:With abnormal voltage display function, the system

    can show high and low voltage

  • Addressable Devices’ External Connection Function:Connected to the communication module

    adopted the two-wire transmission can be connected with addressable modules

    or addressable detectors using SLC branch. Feedback message can be displayed by address point.

  • Connection with up to 15 Intelligent Fire Alarm Annunciator Panels

YF-1 Conventional
Fire Alarm Control Panel

  • Two Stage Accumulation Function: Circuit detection requires a period of accumulation time to reset the detector, and detection of the second stage of accumulation, thus reducing the chances of a false alarm caused by interference from ordinary circuits, and improving the dependability of the Central Control Unit.

  • Stand-by Battery Protection System: During blackout, if the stand-by battery has discharged to below DC18V, it will automatically stop discharging, thus increasing battery life.
  • Quality Control: The control panel switches and all of the base board components of this unit are all certified by CNS and CE. All units must pass stringent quality inspections before leaving the factory, ensuring that each will be performing as expected.

  • User-friendly Design: All circuit boards use a modular design; the external lines are also separated from the terminal circuit board, with protections implemented on the input end. If a faulty power supply is connected to the circuit board caused fault, only the affected circuit board needs to be exchanged without disconnecting the external lines, thus greatly improving maintenance and inspection efficiency.

  • Exterior Design: This unit’s circuit display uses high-end heat-resistant plastic, making its stream-lined exterior poised and elegant. With the circuits accessorized with indication plates, it makes all information regarding the buildings, floors and circuit properties clear at a glance.

  • Other Application: This Central Control can also be collocated into a 3-in-1 system with our Broadcast Host and Emergency Telephone Unit, creating a system that both looks and performs like a unity, and enhance the beauty of in-site use.


YFR-1 Addressable Fire
Alarm Control Panel

  • Two-wire Circuits for supper long transmission distance (up to 2km between the control panel and modules)
  • The data memory device can store 2000 historical data records permanently.
  • Sound guidance function (while operating)
  • Abnormal temperature protection function (I/O modules overloading)
  • SLCs, IDCs are equipped with insulation false inspection function
  • Protection against lightening surge
  • I/O modules miswiring protection equipments are available
  • I/O modules are equipped with isolated segment function
  • Weekly automatic test function
  • Repeat alarm function
  • Two-stage fire alarm delay function
  • Standby battery with saving electricity function
  • Expandable with 17” color touch screen, multiple functions for customers to select: remote control or monitor system software
  • (Touch screen) Disaster Prevention Center Control Panel
  • Communication Speed: when a new alarm announcement activates, the inspection time is less than 500ms.
  • Up to 2,048 addresses for addressable devices
  • Serial relay interface: up to 2,040 contacts are available
  • Available to connect with 8 addressable fire alarm control panels to form a large fire monitoring
  • Up to 16 addressable annunciators can be connected
  • Equipped with 3 sets of RS-485 communication ports to connect with a central PC’s monitoring and control system

YRR-04

  • This Fire Manual Station can quickly transmit a signal to the fire receiver terminals or the repeaters while the button under a transparent protective cover has been pushed at the first finding of a fire accident. (This signal is beyond the accumulated time limitation.)
  • There is a light over the button. The light will light up as a signal has been exactly received by the receiver terminal. There is also a telephone jack for telephone communication with attendant at the fire receiver terminal.
  • Auto-Return by pushing button, no need to disassemble the main body.
  • Response light available to identify the operation completed
  • Reinforced transparent protective cover is reusable.
  • All plastics are fire-proof, light, convenient and stylish.
  • Outside cord distribution with terminators to ease on work

YFM-01 Manual
Call Point

  • Auto-Return by pushing button, no need to disassemble the main body.
  • Response light available to identify the operation completed.
  • Reinforced transparent protective cover is reusable.
  • All parts are flame retardant plastic
  • Easy connection through terminators

YSD-02 Photoelectric
Smoke Detector

  • With photoelectric sensing principle, this kind of detector is activated more quickly, accurately and reliably, and there is no false alarm due to chemicals, leaked gas or external light.
  • Ensure repeated and durable use, easy maintenance. Clean interior by removing external case.
  • Due-colored LEDs display separately to easily and quickly identify the status of the detector.
  • Using the diameter 0.5mm anti-insect net avoid insect and dust getting into, as well as make the inflow of smoke smoothly.
  • Connection wires are non-polarized to avoid error wiring.

YFD-01 Fixed Temperature
Heat Detector

  • Adopt bimetal mechanism and UL approval sensor to ensure staile performance, long-term durability and fewer malfunctions.
  • The base is as same as other type of our detectors for easy installation.
  • Connections are non-polarized to avoid wiring mistakes.
  • Red indication lamp lights when detector is activated.
  • High-temperature enduring plastic are used to build up the main body.
  • Sealed sensor to prevent from moisture and dust entering and maintain the performance.
  • Auto-reset to original status for repeated using.
  • Pure silver contacts ensure quick response.

YRR-13 Addressable
Photoelectric Smoke
Detector

  • Address coding by dip switch
  • Two-wires multi-transmission
  • With the function of photoelectric sensor, it can act rapidly and accurately with high stability. Also, it won’t cause false alarms by chemistry substance, gas leakage or external light.
  • Steel insect-proof nets with the hole size of 0.5 mm ensure smooth inflow of smoke and prevent insects or dust entering into the detector.
  • The detector doesn’t contain any radioactive substances, and no harm to humans or animals.
  • The detector is reusable and easy maintenance. Remove the cover to clean the interior.
  • The detector is made of flameproof and high temperature-resistant plastic.

YRR-12 Addressable Fixed
Temperature Heat Detector

  • Address coding by dip switch
  • Two-wires multi-transmission
  • With the function of photoelectric sensor, it can act rapidly and accurately with high stability. Also, it won’t cause false alarms by chemistry substance, gas leakage or external light.
  • Steel insect-proof nets with the hole size of 0.5 mm ensure smooth inflow of smoke and prevent insects or dust entering into the detector.
  • The detector doesn’t contain any radioactive substances, and no harm to humans or animals.
  • The detector is reusable and easy maintenance. Remove the cover to clean the interior.
  • The detector is made of flameproof and high temperature-resistant plastic.

YRR-11 Addressable
Rate of Rise Heat Detector

  • Address coding by dip switch
  • Two-wires multi-transmission.
  • It’s available to connect with general detectors.
  • It responds immediately when the temperature rises rapidly.
  • High-quality parts are used to ensure the functional reliability.
  • The detector is made of flameproof and high temperature-resistant plastic.

YRD-01 Rate of
Rise Heat Detector

  • Quickly responds to rapid temperature increase
  • Self-restoring elements for repeated use
  • Mechanical operating principles ensure the long-term durability and the least malfunction
  • Red indicating lamp lights when detector is activated
  • High-temperature-enduring plastic and fire-proof material
  • Easy installation and storage
  • Non-polarized connections to avoid wiring mistakes

YRR-3LI

  • Input voltage: 24V DC
  • Communication circuit resistance: below 10KΩ / circuit
  • Operating environment: 0°C~50°C relatif humidity below 85%
  • Monitoring current: 27mA / 24V DC
  • Operating voltage: 21~33V AC.
  • Material: Flame retardant plastic
  • Dimension: 87 x 93.5 x 43 mm
  • Note: Dedicated TYY Addressable EOL resistor

YRR-3L0

  • Input voltage: 24V DC
  • Communication circuit resistance: below 10KΩ / circuit
  • Operating environment: 0°C~50°C relatif humidity below 85%
  • Monitoring current: 27mA / 24V DC
  • Operating voltage: 21~33V AC.
  • Material: Flame retardant plastic
  • Dimension: 87 x 93.5 x 43 mm
  • Note: Dedicated TYY Addressable EOL resistor

YRR-4LI

  • Input voltage: 24V DC
  • Communication circuit resistance: below 10KΩ / circuit
  • Operating environment: 0°C~50°C relatif humidity below 85%
  • Monitoring current: 27mA / 24V DC
  • Operating voltage: 21~33V AC.
  • Material: Flame retardant plastic
  • Dimension: 87 x 93.5 x 43 mm
  • Note: Dedicated TYY Addressable EOL resistor

YRR-4L0

  • Input voltage: 24V DC
  • Communication circuit resistance: below 10KΩ / circuit
  • Operating environment: 0°C~50°C relatif humidity below 85%
  • Monitoring current: 27mA / 24V DC
  • Operating voltage: 21~33V AC.
  • Material: Flame retardant plastic
  • Dimension: 87 x 93.5 x 43 mm
  • Note: Dedicated TYY Addressable EOL resistor

RY-01 Voltage Control
Output Module

  • Used to control the electrical isolation between the higher power peripheral devices and modules.
  • With voltage control output.
  • Equipped with overload fuse to automatically provide protection when the power supply is abnormal.
  • Two LEDs to indicate action and overload situations.
  • Use large terminal block to ensure the wiring security.

RY-02 Voltage-free Control
Output Module

  • Used to control the electrical isolation between the higher power peripheral devices and modules.
  • With voltage-free control output.
  • With action LED indicator.
  • Use large terminal block to ensure the wiring security.

YRR-21 Isolation Module

  • Isolation module for addressable Signaling Line Circuit loops.
  • Recommend to use one Isolation Module for every or less than 23 addressable equipment.
  • Equipped with Isolation short circuit indicating lamp.
  • Not occupy address.
  • Deploy at main line for branching purpose: Isolation module deploys between
    main line and branch line, when short circuit happens, the isolation module will auto-isolate
    the error part with the main line, thus avoiding the whole zone break-down.

YRR-02 Addressable
Monitor/Repeater Module

  • It has On-board indicators for the status of “Monitoring,” Activate,” and “Error.”
  • Address coding by binary coded dip switch for easier setting.
  • Two-wires multi-transmission.
  • Stable communication with rejection to noise and disturbances.
  • On-board self-test functions for circuit disconnection and activation.
  • Expandable to connect with photoelectric smoke, rate of rise heat and fixed temperature heat detectors.
  • On-board voltage control output, activation confirmation function.
  • Communication isolation functions, when short circuit occurring in the module, it will be automatically -isolated from the main communication line.
  • Output 24VDC can directly connect with all kinds of systems.
  • Light indication pattern (fire: red light constantly on, disconnection: red light flashing, monitoring: red light flashing once per 2.5s).
  • Alumina rail lock structure, easy to install.

YFB-B6

  • Rated voltage: DC24V / DC12V
  • Rated current: 30mA / 60mA
  • Volume: 90dB
  • Power source: Motor
  • Material: 3.0mm Alloy Alu
  • Weight: 414g
  • Color: Red

YIL-01

  • Rated voltage: 24V DC
  • Rated current: 100μA max
  • Material: Plastic fireproof
  • Weight: 55g
  • Color: Red
  • Crust designed lamps and refractory substrates and withstand bumps
  • Crust lights are designed to increase the lamp brightness

FS-100A

  • Operating voltage and current: 12V-28VDC, (typical voltage: DC 24V)
                                                    Siren: 40mA
                                                    Strobe: 250mA (at DC 24V)
  • Siren tone: sweep, bell, whistle, etc.
  • Siren output: 105 +/- 3dB (at 1 meter)
  • Size(mm): 82(L) x 82(W) x 34(H)
  • Powe cord: 1 ft. (AWG 24) in general
  • Color: ivory + red lens, red + red lens
  • Packing: 1 pc/box: 50pcs/inner ctn.; 100pcs/ctn.
                     N.W/G.W/MEST: 14.5Kgs/16Kgs/2.3'